Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Acta cir. bras ; 34(6): e201900608, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1019267

RESUMO

Abstract Purpose To analyze the resistance to medial traction of abdominal wall muscles, before and after performing relaxing incisions. Methods Seventeen live pigs were used. After a median laparotomy, the handles were made in the rectus abdominis muscles (RAM) to fit the dynamometer. Step 1 (control phase): tensile strength measured without performing relaxant incisions. Step 2: A curvilinear relaxant incision was made on the anterior blade of the right RAM sheath and then the tensile strength was measured by the edge of the wound. The same procedure was adopted after incision of the left posterior blade. Step 3: Relaxing incisions were made in the right posterior and left anterior blade, so that both sides were left with a relaxing incision on both blades. Measurements of resistance were performed. Results There was no statistically significant difference between the sides. On the right and left side, all treatments reduced the tensile strength when compared to each other and to the control. There was a reduction of 12% and 9.8% after incision of the anterior and posterior blade, respectively. Conclusion Relaxing incisions reduced tensile strength in the ventral abdominal wall.


Assuntos
Animais , Resistência à Tração/fisiologia , Músculos Abdominais/cirurgia , Parede Abdominal/cirurgia , Laparotomia/métodos , Suínos , Cicatrização/fisiologia , Técnicas de Sutura , Músculos Abdominais/fisiologia
2.
São José dos Campos; s.n; 2018. 117 p. il., tab., graf..
Tese em Português | BBO, LILACS | ID: biblio-1015980

RESUMO

O objetivo desse estudo foi analisar a interface adesiva do sistema adesivo Single Bond Universal (SBU) em dentina submetida à diferentes protocolos de condicionamento ácido em 24 h e 12 meses. E a degradação colagenolítica (DC) mediada por metaloproteinases (MMPs) e Catepsina-K (CAT-K) em tempo imediato. Esse estudo foi conduzido em 3 etapas: 1) Caracterização química da dentina em FTIR; 2) DC por meio de fragmentos do Telelopeptídeo Carboxiterminal do Colágeno Tipo I (ICTP) e do Terminal C do Telopeptídeo ligado ao Colágeno Tipo I (CTX) e a resistência à tração (RT) da do colágeno; 3) Análise da interface adesiva através da resistência de união (RU), análise de fratura, microscopia eletrônica de varredura (MEV) e nanoinfiltração (NI). Para FTIR foram utilizados 6 discos de dentina, divididos em 2 grupos: 1) Ácido fosfórico 32 %15 s (AF), 2) Ácido poliacrílico 25 % 10 s (AP). Para análise da DC, 12 discos de dentina foram completamente desmineralizados e divididos em 3 grupos: 1) AF, 2) AP e 3) Água deionizada (Controle) 15 s. Após, foram incubados e armazenados por 1 semana. Seguindo-se a análise da concentração de proteína total (PT). 50 µl da solução de incubação foram utilizadas para analisar ICTP e CTX. As concentrações foram calculadas em relação à PT. Para RT, foram testados 36 palitos obtidos dos discos de colágeno. Para RU foram utilizados 48 dentes, divididos em 2 grupos, de acordo com o período de armazenamento, divididos em três subgrupos: 1) AF, 2) AP e 3) Autocondicionante SBU 20 s (SE). Os dentes foram restaurados e armazenados em água destilada 37 °C. Após, foram submetidos ao teste de microtração e análise de fraturas. Para as análises MEV e NI foram utilizados 2 espécimes de cada subgrupo. Para análise estatística utilizou-se ANOVA 1-Fator, ANOVA- 2 Fatores e teste de Tukey (α=0.05). Para FTIR, AF reduziu a quantidade de fosfato e carbonato quando comparado ao AP. Para DC, a liberação de ICTPPT para AF foi significantemente maior do que para AP (p < 0,05). Não houve diferença na liberação de CTXPT para AF e AP (p > 0,05). Para RT não houve diferença entre AP e Controle, porém, apresentaram valores maiores do que AF (p<0,05). Para RU em MPa, não houve diferença estatisticamente significativa para todos os tratamentos nos diferentes períodos de análise (p < 0,05). A análise de fraturas evidenciou a predominância de fraturas adesivas e mistas. MEV mostrou melhor qualidade da interface após 12 meses para AF e AP. Após 12 meses apenas SE não apresentou NI. Assim sendo, o autocondicionamento ainda parece ser a melhor opção para sistemas adesivos universais que possuam monômeros funcionais em sua composição.(AU)


The aim of this study was to analyze the adhesive interface of the Single Bond Universal (SBU) to dentin submitted to different acid etching protocols in 24 h and 12 months, and the collagenolytic degradation (CD) by matrix metalloproteinases (MMPs) and Cathepsin-K (CAT-K) in the immediate time. This study was divided into three stages: 1) Dentin chemical characterization by FTIR; 2) CD by release of the collagen telopeptide fragment cross-linked carboxyterminal telopeptide of type I collagen (ICTP), and C-terminal crosslinked telopeptide of type I collagen (CTX) and ultimate tensile strength (UTS); 3) Analysis of the adhesive interface by microtensile bond strength (µTBS), failure mode, scanning electron microscopy (SEM) of the AI, and nanoleakage by SEM (NL). For FTIR, six dentin disks were divided into two groups: 1) Phosphoric acid 15 s (PA), 2) Polyacrylic acid 10 s (PAA). For CD twelve dentin disks were completely demineralized, then were divided into 3 groups 1) PA, 2) PAA, and 3) deionized water (Control) for 15 s. All disks were incubated in a buffered solution (BS) for 1 week. Total protein (TP) concentrations were measured using Nanodrop™ at 280 nm. 50 µl of BS was used to analyze solubilized telopeptide fragments using ICTP and CTX . ICTP and CTX average ratios were calculated in relation to TP concentration (ICTPtp and CTXtp). For UTS, 36 dentin beams obtained from collagen disks were tested. For µTBS, forty-eight teeth were divided into two groups according to the period of storage, then subdivided into three subgroups: 1) PA, 2) PAA, and 3) Self-etch 20 s (SE). After, composite build up, the specimens were stored in distilled water at 37 °C. Two specimens of each group were used for SEM analysis of AI and NL. Data were analyzed by one-way ANOVA, two-way ANOVA and Tukey tests (p<0.05). According to the results of the FTIR etching with PA reduced the amount of phosphate and carbonate when compared to PAA. ICTPtp release of PA was significantly higher A than PAA (p > 0,05). CTXtp showed no difference between the PA and PAA (p < 0,05). For UTS there was no difference between PAA and control, but they were significantly higher (p<0.05) than PA. For µTBS in MPa, there is no statistical difference among all the etching protocols tested, as well in both storage periods of analysis (p < 0,05). The most prevalent failure mode were adhesives associated with mixed. SEM analysis highlighted a better quality of AI after 12 months for PA and PAA. However, after 12 months only SE did not show NL. Then, the self-etching protocol seems to be a better choice regarding universal adhesive systems which have functional monomers in their blend(AU)


Assuntos
Humanos , Dentina/lesões , Resistência à Tração/fisiologia , Colágeno/administração & dosagem , Metaloproteinases da Matriz/efeitos adversos , Catepsina K/farmacologia
3.
Acta cir. bras ; 32(12): 1045-1055, Dec. 2017. graf
Artigo em Inglês | LILACS | ID: biblio-886197

RESUMO

Abstract Purpose: To evaluate the effect of transforming growth factor β1 (TGF-β1) on tendon-to-bone reconstruction of rotator cuff tears. Methods: Seventy-two rat supraspinatus tendons were transected and reconstructed in situ. At 8 and 16 weeks, specimens of three groups; that is control, L-dose (low dose), and H-dose (high dose) were harvested and underwent a biomechanical test to evaluate the maximum load and stiffness values. Histology sections of the tendon-to-bone interface were identified by hematoxylin-eosin or Masson trichrome stain. Collagen type III was observed by picric acid sirius red staining under polarized light. The level of insulin-like growth factor 1 (IGF-1) and vascular endothelial growth factor (VEGF) was measured by the enzyme-linked immunosorbent assay (ELISA) method. Results: Collagen type III of the H-dose group had a significant difference in histology structure compared with the L-dose group (P<0.05). The maximum load and stiffness decreased significantly in the control group compared with the values of the L-dose and H-dose groups. The stiffness among the three groups differed significantly at the same postoperative time (P<0.05). Interestingly, progressive reestablishment of collagen type III affected tendon-to-bone healing significantly in the later stages. Conclusion: The H-dose was associated with an increased collagen type III morphology stimulated by TGF-β1.


Assuntos
Animais , Masculino , Ratos , Traumatismos dos Tendões/tratamento farmacológico , Cicatrização/fisiologia , Manguito Rotador/cirurgia , Fatores de Crescimento do Endotélio Vascular/metabolismo , Fator de Crescimento Transformador beta1/metabolismo , Lesões do Manguito Rotador/cirurgia , Traumatismos dos Tendões/metabolismo , Resistência à Tração/fisiologia , Cicatrização/efeitos dos fármacos , Fenômenos Biomecânicos , Ensaio de Imunoadsorção Enzimática , Manguito Rotador/metabolismo , Ratos Sprague-Dawley , Colágeno Tipo III/metabolismo , Modelos Animais de Doenças , Elasticidade/fisiologia , Fator de Crescimento Transformador beta1/farmacologia , Força Muscular/fisiologia , Fibroblastos/efeitos dos fármacos , Fibroblastos/fisiologia , Lesões do Manguito Rotador/metabolismo
4.
Acta cir. bras ; 31(5): 294-299, May 2016. graf
Artigo em Inglês | LILACS | ID: lil-783797

RESUMO

ABSTRACT PURPOSE: To compare fibroplasia and the resistance of the abdominal wall when polypropylene meshes and polypropylene/poliglecaprone are used. METHODS: Seventy-seven male Wistar rats were divided into three groups: Control Group (for resistance); Group E (polypropylene mesh); and Group U (polypropylene/poliglecaprone mesh). The animals in Groups E and U had a standard muscular and aponeurotic defect, with integral peritoneum, and correction with the mesh. Measurements were taken 4, 7, 14, 28 and 56 days after surgery. The resistance, and collagen density were studied. RESULTS: Resistance on the 56th day was similar in both meshes. The gain in resistance described an ascending curve for the polypropylene mesh and was irregular in the case of the polypropylene/poliglecaprone. Fibroplasia showed a gain in type I and type III collagen in both groups (p<0.001). Collagen III stabilized in the 14th day and collagen I continued to ascend. CONCLUSIONS: The gain in resistance of the polypropylene mesh is regular and ascending, whereas the polypropylene/poliglecaprone is not regular. The final resistance of both meshes is similar; the collagen density increases over time, and show the same inflammatory potential.


Assuntos
Animais , Masculino , Poliésteres/uso terapêutico , Polipropilenos/uso terapêutico , Colágeno/metabolismo , Parede Abdominal/cirurgia , Dioxanos/uso terapêutico , Hérnia Incisional/cirurgia , Período Pós-Operatório , Resistência à Tração/fisiologia , Teste de Materiais/instrumentação , Ratos Wistar , Modelos Animais , Colágeno Tipo I/metabolismo , Colágeno Tipo III/metabolismo , Hérnia Incisional/fisiopatologia , Hérnia Incisional/metabolismo
5.
Biol. Res ; 48: 1-8, 2015. graf, tab
Artigo em Inglês | LILACS | ID: biblio-950789

RESUMO

BACKGROUND: Mechanical strain plays a great role in growth and differentiation of osteoblast. A previous study indicated that integrin-ß (ß1, ß5) mediated osteoblast proliferation promoted by mechanical tensile strain. However, the involvement of integrin-ß; in osteoblastic differentiation and extracellular matrix (ECM) formation induced by mechanical tensile strain, remains unclear. RESULTS: After transfection with integrin-ß1 siRNA or integrin-ß5 siRNA, mouse MC3T3-E1 preosteoblasts were cultured in cell culture dishes and stimulated with mechanical tensile strain of 2500 microstrain (µÎµ) at 0.5 Hz applied once a day for 1 h over 3 or 5 consecutive days. The cyclic tensile strain promoted osteoblastic differentiation of MC3T3-E1 cells. Transfection with integrin-ß1 siRNA attenuated the osteoblastic diffenentiation induced by the tensile strain. By contrast, transfection with integrin-ß5 siRNA had little effect on the osteoblastic differentiation induced by thestrain. At thesametime, theresultofECM formation promoted by the strain, was similar to the osteoblastic differentiation. CONCLUSION: Integrin-ß1 mediates osteoblast differentiation and osteoblastic ECM formation promoted by cyclic tensile strain, and integrin-ß5 is not involved in the osteoblasts response to the tensile strain.


Assuntos
Animais , Camundongos , Osteoblastos/fisiologia , Resistência à Tração/fisiologia , Diferenciação Celular/fisiologia , Integrina beta1/fisiologia , Cadeias beta de Integrinas/fisiologia , Matriz Extracelular/fisiologia , Estresse Mecânico , Transfecção , Linhagem Celular , Western Blotting , RNA Interferente Pequeno , Proliferação de Células/fisiologia , Reação em Cadeia da Polimerase em Tempo Real
6.
Acta cir. bras ; 28(10): 703-707, Oct. 2013. ilus, tab
Artigo em Inglês | LILACS | ID: lil-687743

RESUMO

PURPOSE: To evaluate the effects of acute alcohol intoxication on healing of colonic anastomosis. METHODS: Thirty-six rats were allocated into two groups. Animals in the alcohol (A) were given 2 mL of ethanol diluted in 0.9% saline solution to a concentration of 40% by gavage immediately before anesthesia, whereas control (C) animals received 2 mL of 0.9% saline solution via the same route. A colonic anastomosis was then performed in all animals. On postoperative days 1, 3, and 7, anastomotic breaking strength was assessed and histopathological examination was performed. Change in body weight and mortality were also evaluated. RESULTS: The median of anastomotic tensile strength on the postoperative day 1 was 0.09 Newtons for group A and 0.13 for group C. (p>0.05). The median of anastomotic tensile strength on the postoperative day 3 was 0.13 Newtons for group A and 0.17 for group C. (p>0.05). The median of anastomotic tensile strength on the postoperative day 7 was 0.30 Newtons for group A and 0.35 for group C. (p>0.05). There was no significant difference between the groups A and C, in the first, third or seventh POD (p>0.05), in any of the analyzed parameters. There were no statistical differences between groups in the weight. Three animals died, all from the group A. CONCLUSION: Acute alcohol intoxication did not interfere with wound healing of colonic anastomoses, although it caused early postoperative mortality.


Assuntos
Animais , Humanos , Masculino , Ratos , Intoxicação Alcoólica/fisiopatologia , Colo/cirurgia , Resistência à Tração/fisiologia , Cicatrização/fisiologia , Anastomose Cirúrgica , Intoxicação Alcoólica/patologia , Modelos Animais de Doenças , Período Pós-Operatório , Distribuição Aleatória , Ratos Wistar
7.
Acta cir. bras ; 28(6): 447-452, June 2013. ilus, tab
Artigo em Inglês | LILACS | ID: lil-675580

RESUMO

PURPOSE: To investigate the correlation between bursting pressure and breaking strength on the 7th postoperative day following left colonic anastomosis in rats. METHODS: Seventy rats were randomly divided into seven groups of ten animals each. All of the animals underwent segmental resection of the left colon and end-to-end anastomosis. The animals in groups I to VI underwent surgical laparoscopies with pneumoperitoneums using carbon dioxide or helium at pressures of 5, 12 or 20 mmHg. In Group VII, open laparotomy was performed. The animals were reoperated on postoperative day 7 to measure the bursting pressure and the breaking strength of the anastomosis. RESULTS: The anastomosis bursting pressure in 70 animals was 193.10±55.56 mmHg. There was no significant difference between the groups (p=0.786). The breaking strength of the anastomosis was 0.26±0.12 N. There was no significant difference between the groups (p=0.356). Pearson's correlation test showed a low correlation (r=0.231) lacking statistical significance (p=0.054). CONCLUSION: There was no correlation between the bursting pressure and breaking strength of left colonic anastomoses in rats on the 7th postoperative day.


Assuntos
Animais , Masculino , Ratos , Colo/cirurgia , Pressão , Resistência à Tração/fisiologia , Anastomose Cirúrgica , Colo/patologia , Pneumoperitônio Artificial , Período Pós-Operatório , Pressão/efeitos adversos , Distribuição Aleatória , Ratos Wistar , Valores de Referência , Fatores de Tempo , Aderências Teciduais , Cicatrização/fisiologia
8.
Acta cir. bras ; 27(3): 236-243, Mar. 2012. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-617963

RESUMO

PURPOSE: To study the effect of alcoholism on intestinal healing and postoperative complications in rats METHODS: One hundred and sixty rats were divided into two groups: control and treated. The control group received water and the treated group 30 percent ethanol. After 180 days, colotomy with anastomosis were performed. After, the groups were divided into four subgroups: 20 rats for study at the following moments: 4th, 7th, 14th and 21st postoperative. The analyzed parameters were: weight gain, breaking strength, tissue hydroxyproline, postoperative complications and histopathological study RESULTS: Weight gain was greater in the control group (p<0.05). When all the subgroups were clustered, breaking strength was significantly greater in the control (p<0.05). Histopathology and hydroxyproline dosage did not show differences. There were five surgical site infections in the treated group while the control group showed two (p>0.05). Nine fistulas occurred in the treated group whereas the control group two (p<0.05). There were three deaths in the control group and seven in the treated group (p>0.05). CONCLUSIONS: Treated group undergo a malnutrition process that is revealed by lower weight gain. Impaired intestinal healing as indicated by smaller breaking strength. There were a larger number of postoperative complications in the treated animals.


OBJETIVO: Estudar o efeito do alcoolismo no processo de cicatrização intestinal e suas complicações pós-operatórias em ratos. MÉTODOS: Cento e sessenta ratos foram divididos em dois grupos: tratado e controle. O controle recebeu água, enquanto o tratado etanol a 30 por cento. Após 180 dias foram realizadas colotomia, seguida de anastomose. Após os animais foram divididos em quatro subgrupos de 20 ratos para estudo nos seguintes momentos: 4º, 7º, 14º e 21º pós-operatório. Os parâmetros analisados foram: ganho de peso, força de ruptura, hidroxiprolina tecidual, complicações pós-operatórias e estudo histopatológico. RESULTADOS: O ganho de peso foi superior no grupo controle (p<0,05). Após agrupamento dos momentos a força de ruptura foi superior no controle (p<0,05). Não houve diferença quanto à histopatologia e hidroxiprolina. Houve cinco infecções de incisão no grupo tratado, enquanto no controle ocorreram duas (p>0,05). Houve nove fístulas no grupo tratado, enquanto no controle duas (p<0,05). Ocorreram sete mortes no grupo tratado e apenas três no controle (p>0,05). CONCLUSÕES: No grupo tratado ocorreu um processo de subnutrição evidenciado pelo menor ganho de peso. Piora na cicatrização intestinal, indicada pela menor força de ruptura. Ocorreu um maior número de complicações pós-operatórias no grupo tratado.


Assuntos
Animais , Ratos , Alcoolismo/complicações , Colo/cirurgia , Etanol/administração & dosagem , Fístula Intestinal/etiologia , Peritonite/etiologia , Cicatrização/fisiologia , Anastomose Cirúrgica/efeitos adversos , Distribuição de Qui-Quadrado , Modelos Animais de Doenças , Desnutrição/etiologia , Período Pós-Operatório , Distribuição Aleatória , Ratos Wistar , Deiscência da Ferida Operatória/fisiopatologia , Infecção da Ferida Cirúrgica/etiologia , Resistência à Tração/fisiologia , Aumento de Peso/fisiologia
9.
Acta cir. bras ; 27(1): 63-70, Jan. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-607998

RESUMO

PURPOSE: To evaluate the influence of carbon dioxide pneumoperitoneum on abdominal wall wound healing in rats. METHODS: Eighty rats underwent laparotomy, segmental left colon resection, and anastomosis. The animals were divided into three experimental groups and one control group: EI = pneumoperitoneum for 30 minutes before laparotomy (n=20); EII = pneumoperitoneum for 30 minutes after abdominal closure (n=20); EIII = pneumoperitoneum for 30 minutes before laparotomy and 30 minutes after abdominal closure (n=20); C = control group, without pneumoperitoneum (n=20). In each group, 10 animals were killed 7 days and 10 animals 14 days postoperatively. A segment of the abdominal wall was resected and subjected to tensile strength testing. Another segment of abdominal muscle was used for histopathological analysis; the specimens were fixed in formalin and stained with hematoxylin and eosin. RESULTS: There were no differences in histopathology and tensile strength values among animals in the experimental and control groups 7 or 14 days after surgery. CONCLUSION: Under the present experimental conditions, carbon dioxide pneumoperitoneum did not interfere with abdominal wall wound healing.


OBJETIVO: Avaliar a influência do pneumoperitônio com dióxido de carbono na cicatrização da ferida operatória na parede abdominal de ratos. MÉTODOS: Oitenta ratos foram submetidos à laparotomia, ressecção de segmento do cólon esquerdo e anastomose. Os animais foram distribuídos em quatro grupos de 20 ratos, três experimentais e um controle: Grupo EI = pneumoperitônio por 30 minutos antes da laparotomia. Grupo EII = pneumoperitônio por 30 minutos após a laparorrafia. Grupo EIII = pneumoperitônio por 30 minutos antes da laparotomia e 30 após a laparorrafia. Grupo C = controle, sem pneumoperitônio. Realizou-se, em cada grupo, a eutanásia de 10 animais no 7° e no 14° dia pós-operatório. Um segmento da parede abdominal foi ressecado e submetido à medida da resistência. Outro segmento muscular abdominal foi destinado à análise histopatológica, as peças foram fixadas em formol e as lâminas coradas com hematoxilina e eosina. RESULTADOS: Não houve diferença, à histopatologia e na força de ruptura, entre os animais dos grupos experimentais e do controle no 7° ou 14° dia pós-operatório. CONCLUSÃO: Nas condições em que o experimento foi realizado, o pneumoperitônio com dióxido de carbono não interferiu na cicatrização da parede abdominal.


Assuntos
Animais , Masculino , Ratos , Parede Abdominal/cirurgia , Dióxido de Carbono/administração & dosagem , Colo/cirurgia , Pneumoperitônio Artificial/efeitos adversos , Resistência à Tração/fisiologia , Cicatrização/fisiologia , Anastomose Cirúrgica , Avaliação Pré-Clínica de Medicamentos , Pneumoperitônio Artificial/métodos , Distribuição Aleatória , Ratos Wistar
10.
Acta ortop. bras ; 20(1): 17-20, 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-616921

RESUMO

OBJETIVO: Analisar as tensões geradas no corpo vertebral L4 quando submetida à força de compressão, utilizando a técnica da fotoelasticidade de transmissão. MÉTODOS: Doze modelos fotoelásticos foram utilizados e divididos em três grupos, sendo cada grupo formado por quatro modelos, de acordo com a localização do corte sagital nas vértebras L4-L5 (cortes A, B e C). A simulação foi realizada utilizando uma força compressão de 15 N e as ordens de franjas foram avaliadas no corpo vertebral L4 utilizando o método de compensação de Tardy. RESULTADOS: A análise fotoelástica mostrou que em geral, as tensões se distribuíram de forma homogênea nos corpos vertebrais. As tensões no corte C foram maiores que no B, que por sua vez foram maiores que no corte A. CONCLUSÃO: A região posterior do corpo vertebral L4, principalmente no corte C, apresentou maiores concentrações de tensões, sendo assim, é a área mais susceptível à fratura vertebral e à espondilolistese. Análises econômicas e de decisão. Desenvolvimento de modelo econômico ou de decisão, Nível de evidência I.


OBJECTIVE: to analyze the shear forces on the vertebral body L4 when submitted to a compression force by means of transmission photoelasticity. METHODS: Twelve photoelastic models were divided into three groups, with four models per group, according to the positioning of the sagittal section vertebrae L4-L5 (sections A, B and C). The simulation was performed using a 15N compression force, and the fringe orders were evaluated in the vertebral body L4 by the Tardy compensation method. RESULTS: Photoelastic analysis showed, in general, a homogeneous distribution in the vertebral bodies. The shear forces were higher in section C than B, and higher in B than A. CONCLUSION: The posterior area of L4, mainly in section C, showed higher shear concentrations, corresponding to a more susceptible area for bone fracture and spondylolisthesis. Economic and Decision Analyses - Development of an Economic or Decision Model. Level I.


Assuntos
Humanos , Osteoporose , Região Lombossacral/lesões , Resistência à Tração/fisiologia , Coluna Vertebral , Fenômenos Biomecânicos
11.
Full dent. sci ; 1(2): 117-128, Aug. 15, 2010.
Artigo em Português | LILACS, BBO | ID: lil-605594

RESUMO

Tradicionalmente, implantes com comprimentos ≥ 10mm apresentaram desempenhos superiores quando comparados com implantes curtos. Contudo, recentemente, estudos publicaram altas taxas de sobrevivência de implantes curtos com diferentes sistemas de implantes. O objetivo desta revisão de literatura é o de avaliar os fatores biomecânicos, possivelmente, responsáveis pelo sucesso do uso de implantes com comprimentos ≤ 8,5mm.


Traditionally, implants with lengths ≥ 10 mm showed superior performance when compared with short implants. However, recently, studies have published high survival rates of short implants with different implant systems. The purpose of this review is to evaluate the biomechanical factors possibly responsible for the success of implants with lengths ≤ 8.5 mm.


Assuntos
Fenômenos Biomecânicos/fisiologia , Implantação Dentária Endóssea , Implantes Dentários/métodos , Osseointegração/fisiologia , Procedimentos Cirúrgicos Operatórios/métodos , Resistência à Tração/fisiologia
12.
Acta cir. bras ; 26(supl.2): 92-99, 2011. graf, tab
Artigo em Inglês | LILACS | ID: lil-602651

RESUMO

PURPOSE: To evaluate the effects of metoclopramide on abdominal wall healing in rats in the presence of sepsis. METHODS: 40 rats divided into two groups of twenty animals, subdivided into two subgroups of 10 animals each: group (E) - treated with metoclopramide, and saline-treated control group. The two groups were divided into subgroups of 10 to be killed on the 3rd day (n = 10) or day 7 (n = 10) after surgery. Sepsis was induced by cecal ligation and puncture. We performed also the section and anastomosis in left colon. The synthesis of the abdominal wall was made with 3-0 silk thread. We measured the breaking strength of the abdominal wall and made the histopathological evaluation. RESULTS: on 3rd day postoperative, the average breaking strength in the E group was 0.83 ± 0.66 and in group C was 0.35 ± 0.46 (p = 0.010). On the seventh day, the breaking strength in group E was11.44 ± 5.07, in group C 11.66 ± 7.38 (p = 1.000). The E7 group showed lower inflammatory infiltration, foreign body reaction, fibrin than control. CONCLUSION: animals treated with metoclopramide had a higher resistance of the abdominal wall on the 3rd postoperative day.


OBJETIVO: Avaliar os efeitos da metoclopramide na cicatrização da parede abdominal de ratos na vigência de sepse. METHODS: 40 ratos divididos em dois grupos de 20 animais, subdivididos em dois subgrupos de 10 animais cada: grupo (E) - tratado com metoclopramida, e o grupo controle tratado com solução fisiologica. Os dois grupos foram divididos em subgrupos de de 10 para serem mortos no dia 3 (n = 10) ou o dia 7 (n = 10) após a cirurgia. A sepse foi induzida por ligadura e perfuração cecal. Foi realizada também a secção e anastomose em cólon esquerdo. A síntese da parede abdominal foi feita com fio de seda 3-0. Mediu-se a força de ruptura da parede abdominal e foi feita uma avaliação histopatológica. RESULTADOS: No dia 3 pós-operatório, a força média de ruptura no grupo E foi de 0,83 ± 0,66 e no grupo C foi de 0,35 ± 0,46 (p = 0,010). No sétimo dia, a força de ruptura no grupo E foi 11.44 ± 5,07; no grupo C, 11,66 ± 7,38 (p = 1,000). O grupo E7 apresentou menor infiltração inflamatória e reação de corpo estranho do que o controle de fibrina. CONCLUSÃO: Animais tratados com metoclopramida apresentaram uma maior resistência da parede abdominal no 3º dia pós-operatório.


Assuntos
Animais , Masculino , Ratos , Parede Abdominal/cirurgia , Antagonistas de Dopamina/farmacologia , Metoclopramida/farmacologia , Sepse/fisiopatologia , Deiscência da Ferida Operatória/fisiopatologia , Cicatrização/efeitos dos fármacos , Anastomose Cirúrgica , Colo/cirurgia , Modelos Animais de Doenças , Período Pós-Operatório , Ratos Wistar , Deiscência da Ferida Operatória/prevenção & controle , Fatores de Tempo , Resistência à Tração/efeitos dos fármacos , Resistência à Tração/fisiologia , Cicatrização/fisiologia
13.
An. acad. bras. ciênc ; 82(1): 145-151, Mar. 2010. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-539321

RESUMO

The in vivo mechanics of the annulus fibrosus of the intervertebral disc is one of biaxial rather than uniaxial loading. The material properties of the annulus are intimately linked to the osmolarity in the tissue. This paper presents biaxial relaxation experiments of canine annulus fibrosus tissue under stepwise changes of external salt concentration. The force tracings show that stresses are strongly dependent on time, salt concentration and orientation. The force tracing signature of are sponse to a change instrain, is one of a jumpin stress that relaxes partly as the new strain is maintained. The force tracing signature of a stepwise change in salt concentration is a progressive monotonous change in stress towards a new equilibrium value. Although the number of samples does not allow any definitive quantitative conclusions, the trends may shed light on the complex interaction among the directionality of forces, strains and fiber orientation on one hand, and on the other hand, the osmolarity of the tissue. The dual response to a change in strain is understood as an immediate response before fluid flows in or out of the tissue, followed by a progressive readjustment of the fluid content in time because of the gradient in fluid chemical potential between the tissue and the surrounding solution.


A mecânica in vivo do anel fibroso do disco intervertebral é baseada em carregamento biaxial ao invés de uniaxial. As propriedades materiais do anel estão intimamente ligadas à osmolaridade no tecido. O artigo apresenta experimentos de relaxação biaxiais do anel fibroso de um tecido canino sob mudanças abruptas na concentração externa de sal. A assinatura da força devido à mudança brusca de salinidade resulta em uma progressiva e monótona mudança na tensão em direção a um novo valor de equilíbrio. Embora o número de amostras não permita nenhuma conclusão quantitativa, as tendências podem abrir uma luz no entendimento das interações complexas na direção das forças, deformações e orientação das fibras por um lado e a osmolaridade do tecido por outro lado. A resposta dual devido à uma mudança na deformação é compreendida como uma resposta imediata antes do fluido escoar para dentro ou para fora do tecido, seguido de uma progressiva readaptação da quantidade de fluido notempo devido ao gradiente do potencial químico entre o tecido e a solução externa.


Assuntos
Animais , Cães , Disco Intervertebral/química , Disco Intervertebral/fisiologia , Salinidade , Resistência à Tração/fisiologia , Fenômenos Biomecânicos , Modelos Biológicos
14.
Acta cir. bras ; 24(1): 57-61, Jan.-Feb. 2009. tab, graf
Artigo em Inglês | LILACS | ID: lil-503107

RESUMO

PURPOSE: To investigate if diabetes mellitus may alter breaking strength (BS) and collagen content in ileum and colon anastomoses in rats. METHODS: Three-hundred Wistar rats were randomly assigned to 5 experimental groups, 60 per group: normal controls surgically manipulated (G1); normal controls submitted to ileum (G2) and colon (G3) anastomotic construction; diabetic rats submitted to ileum (G4) and colon (G5) anastomotic construction. Each group was further divided into 6 subgroups with 10 rats each for sacrifice at 0, 4, 7, 14, 21, and 30 days after surgery. All surgical procedures were performed 3 months after alloxan diabetes induction. BS was measured in all intestinal anastomoses. Fragments of ileum and colon anastomoses were taken for hydroxyproline concentration (HP) and total tissue protein (TP) dosages. RESULTS: Anastomotic BS was significantly decreased (P<0.05) in ileum and colon of G4 and G5 diabetic groups up to 7 and 14 days after surgery, respectively, compared with G2 and G3 normal control groups. Anastomotic HP and TP content did not significantly differ between diabetic and normal control operated groups in ileum or colon at all evaluation times. CONCLUSION: Experimental diabetes leads to impaired intestinal anastomotic strength during early surgical wound repair, but does not appear to be implicated with collagen synthesis capacity.


OBJETIVO: Investigar se o diabetes mellitus pode alterar a força de ruptura (FR) e o conteúdo de colágeno em anastomoses realizadas no íleo e cólon de ratos. MÉTODOS: 300 ratos Wistar foram distribuídos por sorteio em 5 grupos experimentais com 60 animais cada: controle normal manipulado cirurgicamente (G1); normais controles submetidos a anastomoses no íleo (G2) e cólon (G3); ratos diabéticos submetidos a anastomoses no íleo (G4) e cólon (G5). Cada grupo foi dividido em 6 subgrupos com 10 ratos cada para sacrifícios com 0, 4, 7, 14, 21 e 30 dias após as operações. Os procedimentos cirúrgicos foram realizados 3 meses após a indução do diabetes com aloxana. A FR foi medida em todas anastomoses intestinais. Fragmentos de anastomoses do íleo e cólon foram retirados para dosagens de hidroxiprolina (HP) e proteína tecidual total (PT). RESULTADOS: A FR teve significante redução (P<0,05) nos grupos diabéticos G4 e G5, até 7 e 14 dias após a operação, respectivamente, quando comparada à observada nos grupos controles G2 e G3. Não foram observadas diferenças significantes nas dosagens de HP e PT em ratos diabéticos e controles, tanto operados no íleo como no cólon, em todos os momentos de avaliação. CONCLUSÃO: O diabetes conduz a alterações da força de ruptura de anastomoses intestinais durante a fase inicial da reparação da ferida cirúrgica, porém, este fato parece não estar relacionado à capacidade de sintetizar colágeno.


Assuntos
Animais , Masculino , Ratos , Colo/cirurgia , Diabetes Mellitus Experimental/fisiopatologia , Íleo/cirurgia , Resistência à Tração/fisiologia , Cicatrização/fisiologia , Aloxano , Anastomose Cirúrgica , Colágeno/biossíntese , Modelos Animais de Doenças , Distribuição Aleatória , Ratos Wistar
15.
Acta cir. bras ; 23(5): 435-440, Sept.-Oct. 2008. graf
Artigo em Inglês | LILACS | ID: lil-491909

RESUMO

PURPOSE: To study the effect of protein malnutrition on the intestinal wall of rats by evaluating alterations in the rupture force and dosing tissue collagen in the ileum and distal colon. METHODS: One hundred and twenty rats, that had an average weight of 100g, were used. They received water and a standard diet with 20 percent protein during 7 days for adaptation to the diet itself and to environmental conditions. After that period, the animals were randomly distributed in two groups of 60 rats each: Group 1 - the animals received a control diet with 20 percent casein for 21 days; Group 2 - hypoprotein diet with 2 percent casein for 21 days. After the adaptation period, 12 animals of each group were sacrificed at 5 moments: the beginning of experimental period (M0), 4° day (M1), 7° day (M2), 14° day (M3) and 21° day (M4). The diet to the other rats was maintained until the last sacrifice. The following variables were evaluated: body weight, blood albumin rate, tissue's hydroxyproline, hydroxyproline/total protein ratio and rupture strength in the intestinal wall of the ileum and the distal colon. RESULTS: It was observed that the rupture strength in the ileum segment and distal colon was lower in malnourished animals (Group 2); the loss of mechanical resistance was higher in the distal colon segment than in the ileum probably due to the smaller concentration of tissue collagen in the distal colon. CONCLUSION: Protein malnutrition induces the loss of mechanical resistance of the ileum and distal colon and may be associated with a smaller percentage of collagenous tissue formation in the intestinal wall.


OBJETIVO: Avaliar o efeito da desnutrição protéica na parede intestinal do rato através da medida de força de ruptura e dosagem do colágeno tecidual no íleo e cólon distal. MÉTODOS: Foram utilizados 120 ratos, pesando em média 100g, que receberam durante 07 dias uma dieta padrão, contendo 20 por cento de caseína para adaptação dos animais as condições do biotério. Após esse período os animais foram divididos em dois grupos de 60, o controle denominado grupo um que recebeu a dieta padrão, e o grupo teste denominado grupo dois, que recebeu dieta hipoprotéica contendo 2 por cento de caseína. Os dois grupos receberam suas respectivas dietas por um período de 21 dias. Após esse período iniciou-se o sacrifício seqüencial dos animais em ambos os grupos, em número de 12 animais em cada momento, correspondendo ao dia Zero (MO), 4º dia (M1), 7º dia (M2), 14º dia (M3), e 21º dia (M4) sendo mantida a mesma dieta até o final do sacrifício. Em cada momento foram avaliados o peso corpóreo, albumina sanguínea, hidroxiprolina tecidual, relação hidroxiprolina/proteína tecidual e a força de ruptura no segmento ileal e cólico dos animais. RESULTADOS: Observou-se que a força de ruptura do segmento ileal e do cólon distal foi menor nos animais desnutridos (Grupo 2). A perda da resistência mecânica foi maior no segmento do cólon distal do que no segmento ileal, provavelmente pela menor concentração do colágeno tecidual no cólon distal. CONCLUSÃO: A desnutrição protéica induz a diminuição da resistência mecânica no íleo e no cólon distal associado a diminuição do colágeno tecidual na parede intestinal.


Assuntos
Animais , Ratos , Colágeno/análise , Colo/metabolismo , Íleo/metabolismo , Mucosa Intestinal/metabolismo , Desnutrição Proteico-Calórica/metabolismo , Resistência à Tração/fisiologia , Peso Corporal , Colo/lesões , Colo/fisiopatologia , Hidroxiprolina/análise , Íleo/lesões , Íleo/fisiopatologia , Mucosa Intestinal/química , Mucosa Intestinal/fisiopatologia , Desnutrição Proteico-Calórica/fisiopatologia , Proteínas/análise , Distribuição Aleatória , Ratos Wistar , Ruptura/fisiopatologia , Albumina Sérica/análise , Fatores de Tempo
16.
Acta cir. bras ; 23(2): 184-191, Mar.-Apr. 2008. ilus
Artigo em Inglês | LILACS | ID: lil-478756

RESUMO

PURPOSE: To evaluate the Load of Rupture of implants of membranes of microbial cellulose (Zoogloea sp.) and extended polytetrafuoroethylene in sharp defects of abdominal wall of rats. METHODS: Sixty Wistar male rats, with a mean weight of 437,7g ± 40,9, anesthetized by a mixture of ketamine (5mg/100g) and xylazine (2mg/100g), were submitted to a rectangular (2x3cm) excision of the abdominal wall, including fascia, muscle and peritoneum, and treated with membranes of microbial cellulose (MC) (MC Group- 30 animals) or extended polytetrafluoroethylene (ePTFE) (ePTFE Group- 30 animals). Each group was subdivided in 14th POD, 28th POD and 60th POD Subgroups. Under anesthesia, animals were submitted to euthanasia at 14th POD, 28th POD and 60th POD for evaluation of Load of Rupture. RESULTS: Load of Rupture levels were significantly elevated (p<0, 05) among 14th, 28th and 60th postoperative days from each Group. When compared between groups, values of Load of Rupture were significantly larger (p<0, 05) in ePTFE Group than in MC Group. CONCLUSION: Resistance to strength at implant/host interface was more pronounced in PTFEe Group than in MC Group.


OBJETIVO: Avaliar a Carga de Ruptura de implantes de membranas de celulose microbiana (Zoogloea sp.) e de politetrafluoretileno expandido em defeitos agudos produzidos na parede abdominal de ratos. MÉTODOS: Sessenta ratos machos Wistar, com média de peso de 437,7g ± 40,9, anestesiados com uma mistura de cetamina (5mg/100g) e xilazina (2mg/100g), foram submetidos à excisão retangular (2x3cm) na parede ventral do abdômen, incluindo fáscia, músculo e peritônio. Subseqüentemente, foram tratados com implante de membranas de celulose microbiana (CM) (Grupo CM - 30 animais) ou de politetrafluoretileno expandido (PTFEe) (Grupo PTFEe - 30 animais). Cada grupo foi ainda subdividido nos Subgrupos 14º DPO, 28º DPO e 60º DPO. Os animais foram submetidos à eutanásia com doses letais de tiopental no 14º DPO, 28º DPO e 60º DPO, para avaliação da Carga de Ruptura na área do implante. RESULTADOS: Os níveis da Carga de Ruptura foram significativamente elevados (p<0,05) entre os Subgrupos 14º DPO, 28º DPO e 60º DPO de cada grupo estudado. Quando comparados entre Grupos, os valores da Carga de Ruptura foram significativamente maiores (p<0,05) no Grupo PTFEe do que no Grupo CM. CONCLUSÃO: A interface implante/hospedeiro apresentou maior resistência a tração no Grupo PTFEe do que no Grupo CM.


Assuntos
Animais , Masculino , Ratos , Parede Abdominal/cirurgia , Celulose/uso terapêutico , Membranas Artificiais , Politetrafluoretileno/uso terapêutico , Resistência à Tração/fisiologia , Zoogloea , Traumatismos Abdominais/cirurgia , Materiais Biocompatíveis , Fenômenos Biomecânicos , Teste de Materiais , Ratos Wistar , Fatores de Tempo
17.
Rev. chil. ortop. traumatol ; 49(2): 64-70, 2008. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-559488

RESUMO

During everyday activities, bones are submitted to the action of different strengths. While walking, the femur must support loads up to 3 times the body weight. It is for this that the need of knowing the mechanical behavior of the femur submitted to different loads and the place where the fracture would occur is born. This study analyzes, through experimental testing, the maximum resistance of the porcine femur, mechanically comparable to the human femur, submitted to different strengths, to obtain the location of fracture and compare the results obtained with computational simulation and with information described for human femur.


Durante actividades de la vida diaria, los huesos se ven sometidos a la acción de diferentes fuerzas. En la marcha, el fémur debe soportar cargas de hasta 3 veces el peso corporal. Es por esto que nace la inquietud de conocer el comportamiento mecánico del fémur sometido a distintos tipos de cargas, y el lugar de falla donde se produciría una fractura. Este estudio analiza, mediante ensayo experimental, la resistencia máxima del fémur porcino, mecánicamente comparable al fémur humano, frente a distintas cargas, para obtener así el sitio de fractura y luego comparar los resultados obtenidos con simulación computacional y con datos descritos para el fémur humano.


Assuntos
Animais , Fenômenos Biomecânicos , Simulação por Computador , Fraturas do Colo Femoral/fisiopatologia , Modelos Biológicos , Fêmur/fisiologia , Força Compressiva/fisiologia , Valor Preditivo dos Testes , Resistência à Tração/fisiologia , Suínos , Suporte de Carga/fisiologia
18.
Acta cir. bras ; 22(4): 255-259, July-Aug. 2007. ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1456191

RESUMO

PURPOSE: The aim of the present study was to assess, in cadavers, the resistance to medial traction of the posterior and anterior layer of the rectus abdominis muscle sheath. METHODS: An anatomical, prospective, self-controlled study was carried out in 20 male cadavers. An evaluation of the tension of the posterior and anterior layers of the rectus abdominis muscle sheath was performed following anatomical dissection of these structures. The traction necessary to advance the tissue ten millimeters was assessed using an analogic dynamometer. RESULTS: There was no significant statistical difference between the necessary traction at various levels of the anterior and posterior layers of the rectus sheath. However, medial advancement of the anterior layer of the rectus sheath required more traction strength than did advancement of the posterior layer to the midline. CONCLUSION: There is no difference in the tensile strength in the various levels of the anterior and posterior layers of the rectus sheath; however, medial advancement of the the anterior layer required more traction strength.


OBJETIVO: Comparar a resistência à tração medial das lâminas posterior e anterior da bainha do músculo reto do abdome em diferentes níveis supra e infra-umbilicais em cadáveres. MÉTODOS: Vinte cadáveres adultos foram submetidos à dissecção da parede abdominal anterior. Foram feitas alças com fio de náilon no plano aponeurótico em oito pontos diferentes na lâmina anterior e na lâmina posterior da bainha do músculo reto do abdome, sendo quatro destes pontos supra-umbilicais e quatro infra-umbilicais. Com o uso de um dinamômetro analógico, foi verificada a força necessária para o avanço medial de dez milímetros destes dezesseis pontos. RESULTADOS: Não foram encontradas diferenças significantes de medidas da resistência à tração entre os diferentes níveis da aponeurose anterior e posterior, mas quando se comparou as medidas obtidas na aponeurose anterior às obtidas na posterior verificou-se que a aponeurose anterior necessitou de maior força de tração para o avanço medial. CONCLUSÃO: Não há diferença de tensão ao longo da aponeurose anterior e posterior. A aponeurose anterior é mais resistente à tração medial quando comparada à posterior.


Assuntos
Humanos , Músculos Abdominais/anatomia & histologia , Resistência à Tração/fisiologia , Reto do Abdome/anatomia & histologia
19.
Acta cir. bras ; 22(2): 85-91, Mar.-Apr. 2007. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-443682

RESUMO

PURPOSE: To analyze and to evaluate the effect of the hyperbaric hyperoxygenation in the mechanical resistance of ischemic colon of rats. METHODS: Eighty rats, distributed in four groups of 20 animals in each one, were used. In group 1 (G1), the control group, ischemia was not caused. Group 2 was submitted to the lesser degree of ischemia. Group 3 was submitted to the intermediate degree of ischemia. In group 4, a bigger degree of intestinal ischemia was provoked. Each group was divided in two sub-groups of ten animals each: with hyperbaric chamber (CC) and without hyperbaric chamber (SC). The animals of the four CC subgroups were placed in an experimental hyperbaric chamber in order to inhale oxygen at 100 percent, at two Absolute Atmospheres, for 120 minutes, for a four-day consecutive period. The animals of the four SC subgroups were kept in environment air during the five days of the experiment. All animals have been submitted to the mechanical study of the intestinal loop by the pressure test of the rupture by liquid distension. The euthanasia occurred in the fifth post-operative day. RESULTS: Considering the ischemia factor, the four groups were different among them (p=0.0001). There was no statistical difference between subgroups CC and SC (p=0.3461). CONCLUSION: The hyperbaric oxygen-therapy did not present improvement on the induced ischemia in rats upright colic loop.


OBJETIVO: Analisar e avaliar os efeitos da hiperoxigenação hiperbárica na resistência mecânica do cólon isquêmico de ratos. MÉTODOS: Foram utilizados 80 ratos distribuídos em quatro grupos de 20 animais. No grupo 1, grupo controle, não se provocou isquemia. O grupo 2 foi submetido ao grau menor de isquemia. O grupo 3 foi submetido ao grau intermediário de isquemia. No grupo 4, provocou-se grau maior de isquemia intestinal. Cada grupo foi dividido em dois subgrupos de dez animais cada: com câmara hiperbárica (CC) e sem câmara hiperbárica (SC). Os animais dos quatro subgrupos CC foram colocados em uma câmara hiperbárica experimental para inalarem oxigênio a 100 por cento, a duas atmosferas absolutas, durante 120 minutos, por quatro dias consecutivos. Os animais dos quatro subgrupos SC foram mantidos somente em ar ambiente. Todos animais foram submetidos ao estudo mecânico da alça intestinal pelo teste de pressão de ruptura pela distensão por líquido. A eutanásia ocorreu no quinto dia pós-operatório. RESULTADOS: Os quatro grupos são diferentes entre si considerando o fator isquemia (p= 0.0001). Não houve diferença estatística entre os subgrupos CC e SC (p= 0.3461). CONCLUSÃO: A oxigenoterapia hiperbárica não apresentou melhora sobre a isquemia induzida em alça cólica íntegra de ratos.


Assuntos
Animais , Masculino , Ratos , Colo/irrigação sanguínea , Oxigenoterapia Hiperbárica/métodos , Isquemia/terapia , Cicatrização/fisiologia , Anastomose Cirúrgica , Colo/cirurgia , Modelos Animais de Doenças , Ratos Wistar , Estresse Mecânico , Resistência à Tração/fisiologia
20.
Arq. bras. oftalmol ; 70(2): 221-224, mar.-abr. 2007. ilus
Artigo em Português | LILACS | ID: lil-453159

RESUMO

OBJETIVO: Avaliar a ligação entre músculos oculares extrínsecos e esferas de polietileno poroso usando um bioadesivo. MÉTODOS: Estudo experimental envolvendo 8 coelhos albinos submetidos a enucleação do olho direto com colocação de implante esférico de polietileno poroso de 12 mm de diâmetro unido aos músculos oculares extrínsecos por meio do bioadesivo 2-octil-cianoacrilato. Noventa dias após a cirurgia os animais foram sacrificados e o conteúdo orbitário removido. Em 4 animais foi realizado estudo biomecânico, avaliando-se a força de ruptura entre a musculatura e a esfera (grupo implante) e entre a musculatura e a esclera nos olhos contralaterais (grupo controle). Nos outros 4 animais foi realizada análise histológica. RESULTADO: A avaliação biomecânica revelou que a força de ruptura entre esfera-músculo e esclera-músculo foram semelhantes quando se usa o adesivo de cianoacrilato. O exame histológico mostrou reação fibrovascular no local da adesão entre a musculatura e a esfera, sem efeitos deletérios aos tecidos. Ao redor dos implantes foi possível observar pseudocápsula e no interior, neovasos e tecido fibrovascular preenchendo os espaços entre os grânulos do polietileno. CONCLUSÃO: O adesivo 2-octil-cianoacrilato mantém boa força de adesão na união entre os músculos e as esferas de polietileno poroso, com redução do tempo cirúrgico e sem efeitos deletérios aos tecidos orbitais. Desta forma, deve-se considerar o uso do bioadesivo na reconstrução da cavidade anoftálmica.


PURPOSE: To evaluate fixation by a bioadhesive of the external ocular muscles to the porous polyethylene spheres. METHODS: An experimental study was performed using eight white rabbits that underwent right eye enucleation with placement of 12 mm spheres of porous polyethylene. The rectus muscles (superior and inferior) were attached to the implant with a bioadhesive (2-octyl-cyanoacrylate) applied to the inferior side of the external muscles. Ninety days after surgery the orbital content was removed and 4 animals were submitted to a tensile strength test of the muscle-sphere attachment and the other 4 to histological evaluation. RESULTS: The tensile strength test showed that the rupture force was similar between the muscle and porous polyethylene sphere bond attachment and normal external ocular muscles. The histologic evaluation showed fibrous tissue reaction and muscle-sphere attachment with no deleterious effects to the tissues; a capsule formation around the spheres and new vessels inside the implant were also observed. CONCLUSION: 2-octyl-cyanoacrylate provides strength adhesion between muscles and spheres, with surgery time reduction and does not provoke deleterious effects on the orbital tissues. Thus, the bioadhesive might be a good choice for use in the anophthalmic cavity reconstruction.


Assuntos
Animais , Coelhos , Cianoacrilatos/uso terapêutico , Implantes Orbitários , Músculos Oculomotores/efeitos dos fármacos , Órbita/cirurgia , Polietilenos , Adesivos Teciduais/uso terapêutico , Cianoacrilatos , Enucleação Ocular , Modelos Animais , Músculos Oculomotores/cirurgia , Órbita/patologia , Porosidade , Resistência à Tração/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA